Retatrutide
Supplier lot 00011/0011 · Reported September 20, 2026 30mg
SUPPLIER LAB REPORTLaboratory results for the supplier sample identified below. Original client: ROEHN LABS. M Bio lot correspondence has not been confirmed.
Source: ROEHNSample Summary
Identification details from the original supplier certificate.
- Product
- Retatrutide
- Tested presentation
- 30mg
- Supplier batch / Lot
- 00011/0011
- Accession / Report ID
- COA-2026-00288
- Laboratory
- AV Analytics
- Report client
- ROEHN LABS
- Sample received
- September 11, 2026
- Report issued
- September 20, 2026
- Appearance
- Lyophilized
- M Bio lot correspondence
- Not confirmed
Purity Analysis
Results below describe supplier lot 00011/0011.
- Chromatographic purity
- 99.76% (Average of 3 vials)
- Molecular identity
- Conforms: UPLC-MS ionization profile matches standard across all 3 vials
- Assayed content
- Vial 20260900191: 31.09 mg; vial 20260900192: 31.16 mg; vial 20260900193: 30.11 mg
- Test Method
- UPLC-UV (purity); UPLC-MS (identity); quantitative UPLC (net content)
- Endotoxin
- rFC: 0.07 / 0.01 / 0.08 EU/mL. Pass against the laboratory’s <0.5 EU/mL criterion.
What these tests measure
Chromatography assesses the relative proportions of detectable sample components. Mass spectrometry supports molecular identification. Results describe the submitted sample; a matching compound name alone does not establish a shared lot.
Understand purity and net contentFull Certificate PDF
Original certificate issued by AV Analytics. Client, lot identifiers, and document branding are preserved.
If the document preview is blocked by your browser, use Open original PDF .
Supplier Test History
1 supplier certificate linked for Retatrutide.
99.76%Frequently Asked Questions
Whose report is this?
The linked document was issued for the client named on the original certificate. These are external supplier references displayed with their original identifiers.
Does the report certify my M Bio vial?
Only a documented match between your vial’s lot and the tested lot can establish that connection. Sharing a vendor or compound name does not confirm the lot. M Bio lot correspondence is currently unconfirmed.
How can I verify a report?
Use the accession number and original certificate to check the record directly with the laboratory named on the document. Compare the sample identity, nominal amount, lot, dates, and results.
Research Use Only Materials are intended for laboratory research only. Not for human or animal consumption. Results apply only to the sample described in the original certificate.